Lykins Residential Maintenance Program

GAS FURNACE $108.00
OIL FURNACE INCLUDES NOZZLE & FILTER $190.00
BOILER – GAS $114.00
BOILER – OIL INCLUDES NOZZLE & FILTER $200.00
HEAT PUMP – AIR HANDLER (1 VISIT PER YEAR) $160.00
AIR CONDITIONER-H/P ONLY $108.00
A/C & AIR HANDLER (1 VISIT PER YEAR) $160.00
HUMIDIFIER W/PAD (cleaning of furnace) $52.00
ELECTRONIC AIR CLEANER (INCLUDES CHEM) $41.00
GAS WATER HEATER (INCLUDES THERMOCOUPLE) $57.00
STEAM BOILER (RESIDENTIAL ONLY) $134.00

 

HEATING SYSTEM CHECKLIST
1) Check air filters/Replace filters.
2) Tighten electrical connections.
3) Clean blower assembly.
4) Check gas valve.
5) Inspect flue pipe and draft diverter.
6) Check operation of safety controls.
7) Clean and adjust burners.
8) Test and adjust gas pressure.
9) Clean interior of manifold compartment.
10) Check and adjust belt tension.
11) Lubricate all necessary parts.
12) Check baffles and inspect heat exchanger.
13) Clean and adjust thermostat.
14) Test for gas leaks in furnace.
15) Clean and adjust pilot.
16) Check sequencer.
17) Check heating elements.
18) Check furnace in operation.
19) Check CO level.
*Doesn’t include heat exchanger replacement

HUMIDIFIERS
1) Clean housing.
2) Clean drain.
3) Replace water pad.
4) Check operation.

ELECTRONIC AIR CLEANERS
1) Remove and clean cells.
2) Check ionizing wires and insulators.
3) Check power pack.
4) Check operation.
COOLING SYSTEMS
1) Check air filters/Replace filters.
2) Tighten electrical connections.
3) Clean blower assembly.
4) Check operating pressures.
5) Check operation of safety controls.
6) Inspect contractor contacts.
7) Clean and check condenser roil.
8) Check and record superheat.
9) Check and adjust belt tension.
10) Lubricate all necessary parts.
11) Check and record start and run amps.
12) Clean and adjust thermostat.
13) Flush condensate drain lines.
14) Inspect start‐run capacitor.
*Doesn’t cover compressor replacement.
*Doesn’t cover repair of refrigerant leak.

HEAT PUMP SYSTEMS
1) Check reversing valve.
2) Check defrost cycle.
3) Check crankcase heater.

ALSO INCLUDED WITH OIL FURNACES AND BOILERS
1) Replace oil nozzle.
2) Replace oil filter.
3) Check ignition controls.
4) Adjust draft regulator.
5) Clean and check fill valve.
6) Drain expansion tank.
*Doesn’t include draining, refilling, or bleeding of boilers.


If you are interested in our Maintenance Program,with discounts on the above pricing, please fill out the form below and one of our customer service agents will get back with you as soon as possible.